Hydraulic bench for endurance and life tests on sanitary taps according to the main International Standards.
Executable endurance tests:
- Single lever mixers.
- Swivel spouts.
- Thermostatic mixers.
- Diverters.
- Traditional and ceramic single taps.
- Shower mechanisms.
Operative ranges:
- Hot water temperature: up to 85 °C
- Cold water temperature: from 5 °C
- Flow-rate: up to 50 L/min
- Pressure: up to 10 bar
- Torque motor angular speed: from 1 to 180 °/s
- Linear motor speed: from 1 to 300 mm/s
- Maximum torque: 10 Nm
- Maximum force: 44 N
Standard references:
- EN 200
- EN 817
- NF 077
- ASME A112.18.1-2011
- CSA B.125.1-11