Titolo

Hydraulic tests for sanitary taps
En
File allegato: 
Corpo: 

Constant pressure leaktightness tests with adjustable pressure, stabilization time and pressure slopes.
Maximum pressure: 25 bar.
Example of Standard reference: EN 200, EN 817, EN 1111.
Codice: P01
Software: AQ2TB-STATICAUT

Water hammer test with adjustable frequency, minimum and maximum pressure up to 50 bar. Example of Standard reference: NF077 doc.3 - doc.4; Classification ECAU.
Codice: P02
Software: AQ2TB-PULSEAUT

Measurement of the flow-rate of the device under test with step pressure increase. di alimentazione.
The jump pressure and the number of stpes are adjustable.
Example of Standard reference: EN 200, EN 817, EN 1111.
Codice: F05
Software: AQ2TB-FLOW-STEP

Measurement of the flow-rate of the device under test with linear increase of supply pressure. 
Up to 6 tests can be displayed on the same chart to compare different devices or different positions of the same device.
Example of Standards reference: EN 200, EN 817, EN 1111.
Codice: F06
Software: AQ2TB-FLOW-LIN

Test of mixed water temperature fidelity and sensitivity by moving the temperature setting device from cold to hot position and returning to initial position.
The fidelity test evaluates the hysteresis of the control device.
The sensibility test evaluates the minimum angular rotation necessary to change outlet water temperature.
Example of Standard reference: EN 817, EN 1111.
Codice: SF01
Software: AQ2TB-COMBILAB+ / AQ2TB-F+S-DRIVE

Measure of acoustic emission of the hydraulic device under test.
Global evaluation and in bands of frequency of noise generated.
An hydrophone is used to measure the noise emissions.
Example of Standard reference: ISO EN 3822-1, NF S 31-014.
Codice: AT01
Software: AQ2TB-NOISE

Automatic test for evaluation of flow-rate in automatic shut-off valves.
Example of Standard reference: EN 816.
Codice: F07
Software: AQ2TB-LAB-ASV

Measure of flow-rate and force in "water saving" position for single lever mixers.
Measure and acquisition of position, angular speed, torque and flow-rate.
Example of Standard reference: NF 077 doc.3 rev.17.
Codice: SLFM
Software: AQ2TB-SLFM

Measure of water hammer generated by a quick closure of an hydraulic device.
Hydraulic plant realized according to the reference Standard.
High frequency acquisition of pressure signal for an appropriate evaluation of the event.
Example of Standard reference: NF 076 doc.2 rev.9.
Codice: WH01
Software: AQ2TB-HAMTEST

Titolo: 

Hydraulic tests for sanitary taps

News

05
December 2024
23
December 2024
05
December 2024

Contact us

Address

Via dei Crederi, 411
24045 - Fara Gera d'Adda
Bergamo - Italy

Phone/Fax

Ph: (+39) 0363-399019
Fax: (+39) 0363-398725

footerbottom

Giussani Srl - All rights reserved.
VAT: 01496840164

Powered by Weblitz